![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1966153.1 : SL8500 - Can RE IP Addresses (2A & 2B) Be The Same on Both Library Controller Cards ?
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. SL8500 Dual TCP/IP Redundant Electronics Goal SolutionAbsolutely not! 4 unique IP addresses are required and they must not conflict with the internal library addresses(10.0.11.x and below). The 2A and 2B IP addresses MUST be in different subnets on both sides. References<NOTE:1581587.1> - SL8500 - Discussion of Dual TCP/IP and RE IP Addresses and SubnetsAttachments This solution has no attachment |
||||||||||||||||
|