![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1963796.1 : SL8500 - How to Enable SNMP on SL8500 Port 2A on FRS_7.70 and Above
In this Document
Created from <SR 3-9867964561> Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalHow to enable SNMP on SL8500 port 2A. SolutionSL8500 code version should be 7.70 or above. FRS_7.70 SNMP enhancements SL8500> snmp enable port2a requestId requestId 34101 Device 1,0,0,0,1 Success true Done Failure Count 0 Success Count 1 NOTE: If the following error is reported trying to enable snmp on 2A: Number 3301 Check Firmware is at FRS 7.70 or above.
References<NOTE:1631502.1> - SL8500/SL3000 - How to Obtain the Management Information Base / MIB Using SL ConsoleAttachments This solution has no attachment |
||||||||||||||||
|