Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1963796.1
Update Date:2017-09-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1963796.1 :   SL8500 - How to Enable SNMP on SL8500 Port 2A on FRS_7.70 and Above  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Goal
Solution
References


Created from <SR 3-9867964561>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to enable SNMP on SL8500 port 2A.
 

Solution

SL8500 code version should be 7.70 or above.

FRS_7.70 SNMP enhancements
 Allow enable or disable of SNMP over external port 2A (eth5).

SL8500> snmp enable port2a

   requestId

   requestId 34101

   Device  1,0,0,0,1

   Success true

   Done         

   Failure Count 0

   Success Count 1

NOTE: If the following error is reported trying to enable snmp on 2A:

Number 3301
Text Failure from device - resultCode: 4001 - resultText: Feature not implemented returned from snmp enable/disable request

Check Firmware is at FRS 7.70 or above.

 


 

References

<NOTE:1631502.1> - SL8500/SL3000 - How to Obtain the Management Information Base / MIB Using SL Console

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.