![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1963494.1 : FS System: How to Map Connections Between NVDIMM and ESM on FS1-2 Controller
Oracle Confidential PARTNER - Available to partners (SUN). Reason: System board details are for use only by Support Engineers Created from <SR 3-10116059224> Applies to:Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalThe FS1-2 System reports messages related to internal components in different layers. This could create confusion while reading logs, as different address notation has been used in different layers. This document will give brief information about device mapping, and about address notation details for NVDIMM addresses in different layers . SolutionThe FS1-2 Controller has two memory models, named Base and Performance.
The DIMM locations and address details are shown in the picture below for the Performance model.
There are two NVDIMMs and two ESMs in the Base model:
The Netra Server X3-2 8 HDD chassis configuration is used as the base for the FS1-2 Controller. The ESM modules are located in the left side HDD slots HDD0, HDD1, HDD4 and HDD5. The ESM locations, when facing the front of the Controller chassis, are ESM0 and ESM1 bottom from left to right, and ESM2 and ESM3 top from left to right. The FS1-2 Performance model uses all 4 ESMs; the FS1-2 Base model uses only ESM1 and ESM3. Here is the picture showing the locations of the ESM modules in the front view of the Controller:
References<BUG:20384693> - CONTROLLER-01 DISABLED RELATED TO ESM PROBLEM OIS JAPANAttachments This solution has no attachment |
||||||||||||
|