Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1963427.1
Update Date:2017-02-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1963427.1 :   Comp Link Files Coming With Delay for an STP on EMS  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-10045236291>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 45.0 and later
Tekelec

Goal

Measurement Reports are reaching with a delay of about 1 hour on EMS from Eagle STPs

Solution

Check time difference between Eagle STP and EMS.

On the Eagle, run any command to see the timestamp. For example:

rept-stat-trbl

 

 At same time; run following command on EMS:

date

 

 If there is a difference/delay between two timestamps; correct the time.
Change the STP time using following Eagle command.

set-time

 

 