Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1962166.1
Update Date:2017-12-06
Keywords:

Solution Type  Technical Instruction Sure

Solution  1962166.1 :   How to set a Sun Network Switch (ES1-24 or 72P) to factory defaults  


Related Items
  • Sun Blade 6000 10GbE Switched 24p NEM
  •  
  • Sun Network Switch
  •  
  • Oracle Switch ES1-24
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Goal
Solution
References


Applies to:

Oracle Switch ES1-24 - Version All Versions and later
Sun Blade 6000 10GbE Switched 24p NEM - Version Not Applicable and later
Sun Network Switch - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Steps to configure a Sun Ethernet switch SEFOS setup to the factory default.

Solution

From the SEFOS CLI run the command erase startup (not saving the configuration). Then drop back to the ILOM prompt and stop and start sefos.

Here are the steps to reset SEFOS running configuration to the factory default :

SEFOS# show running-configuration
... (copy and paste this output to a text editor and save as text in case you want to refer to it later on)
SEFOS# erase startup-config
SEFOS# exit
Connection closed by foreign host.
cd: The session with /SYS/fs_cli has ended.

-> stop /SYS/sefos
Are you sure you want to stop /SYS/sefos (y/n)? y
stop: SEFOS stopped successfully.

-> start /SYS/sefos
Are you sure you want to start /SYS/sefos (y/n)? y
start: Please wait while sefos comes up, this can take anywhere from 30 seconds to 2 minutes depending on the configuration
..................
start: SEFOS started successfully.

SEFOS# show running-configuration
... (the output should show factory default settings only)

This should now display the factory default SEFOS configuration.

 

Note: The steps above will not reset the ILOM settings .

To reset everything, including the ILOM config, use "set /SP reset_to_defaults=all" from the ILOM prompt.
This will also reset the network settings to the default dhcp.
A serial console will be needed or if the DHCP server assigns the same IP for the switch mgmt-mac-address then it will get configured.

 

References

<NOTE:1399483.1> - 10-Gigabit Ethernet Switches (Opus) Product Page

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback