Asset ID: |
1-71-1960706.1 |
Update Date: | 2018-05-15 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1960706.1
:
How to Replace an Oracle Server X5-2, X6-2 DVD Drive
Related Items |
- Oracle Server X6-2
- Oracle Server X5-2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Part is a FRU not a CRU
Applies to:
Oracle Server X5-2 - Version All Versions to All Versions [Release All Releases]
Oracle Server X6-2 - Version All Versions to All Versions [Release All Releases]
x86_64
Goal
How to Replace an Oracle Server X5-2, X6-2 DVD Drive.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Oracle Server X5-2, X6-2 Training
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: An Oracle Server X5-2, X6-2 DVD Drive needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system.
A data backup is not a prerequisite but is a wise precaution.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare the server for service.
- Remove any media from the DVD drive.
- Power off the server and disconnect the power cords from the power supplies.
- Extend the server to the maintenance position in the rack.
- Attach an anti-static wrist strap.
- Remove the disk cage cover - using a No. 2 Phillips screwdriver, remove six Philips screws from the disk cage cover.
- Slide the cover forward and lift to remove the disk cage cover from the chassis. Set the cover aside.
2. Remove the DVD Drive
- Locate the DVD drive and disconnect the power and data connector from rear of the DVD drive.
- To disengage the DVD drive from the chassis, press and hold the release tab on the rear of the DVD drive up slightly. (The release tab is located on the rear of the drive towards the right side of the system chassis when facing the front of the system.)
- Gently push the DVD drive forward and slide it out the front of the server.
- Place the DVD Drive on an antistatic mat.
3. Install the replacement DVD Drive
- Remove the replacment DVD drive from it's anti-static bag and place on an anti-static mat.
- align the DVD drive with the drive opening at the front of the server.
- Push the replacement DVD drive into the chassis until the release tab on the rear of the drive engages the chassis with an audible click.
- Reconnect the DVD drive power and data connector on the rear of the drive.
4.Return the Server to operation
- Replace the disk cage cover - using a No. 2 Phillips screwdriver, install and tighten the six Philips screws in the disk cage cover.
- Close the Fan access door.
- Remove any anti-static measures that were used.
- Return the server to it's normal operating position within the rack.
- Re-install the AC power cords and any data cables that were removed.
- Power on server. Verify that the Power/OK indicator led lights steady on.
- Verify that the replacement DVD functions properly.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality.
REFERENCE INFORMATION:
Oracle Server X5-2 Documentation:
http://docs.oracle.com/cd/E41059_01/index.html
Oracle Server X5-2 DVD removal procedure:
http://docs.oracle.com/cd/E41059_01/html/E48320/gpiol.html#scrolltoc
Oracle Server X6-2 Documentation:
http://docs.oracle.com/cd/E62159_01/index.html
Oracle Server X6-2 DVD removal procedure:
http://docs.oracle.com/cd/E62159_01/html/E62171/gpiol.html#scrolltoc
Attachments
This solution has no attachment