Solution Type Technical Instruction Sure Solution 1960598.1 : All Nodes lose IB communication when halting or shutting down IB LEAF switch for maintenance
In this Document
Created from <SR 3-10027713804> Applies to:Exadata X4-2 Hardware - Version All Versions and laterExadata X3-2 Hardware - Version All Versions and later Oracle Exadata Hardware - Version 11.1.0.7 to 11.2.3.1.1 [Release 11.1 to 11.2] Information in this document applies to any platform. GoalWhy did all nodes lose communication and reboot when shutting down IB leaf switch ibb01? SolutionShutting down or halting an infiniband switch from the Linux CLI will leave the physical links in the UP state but not responding to SM requests . The active bonds may not fail over resulting Only use supported commands at the switch Linux CLI. See supported commands in the "help" output. Note: To reboot a switch, this must be done from the ILOM using /SP/reset Attachments This solution has no attachment |
||||||||||||||
|