Goal
This document describes the steps to perform an EMS backup.
Solution
EMS BACKUP PROCEDURE & VERIFICATION
Establish an SSH connection and login to EMS Server as “netboss”
login as: netboss
Using keyboard-interactive authentication.
Password:
Last login: Thu May 22 13:03:36 2008 from 10.##.#.##
Sun Microsystems Inc. SunOS 5.10 Generic January 2005
You have new mail.
Use Default Display: << localhost:11.0 >> (y/n) ? y
DISPLAY set to localhost:11.0
Do you wish to start the NetBoss menu ( y or n )? N
hostname[netboss]/opt/home/netboss%
2.
Issue the commands to export the contents of the Netboss database to the $ANMDIR/fms/dbunload/export.exp file
hostname[netboss]/app/netboss/misc% $ANMDIR/misc/db_backup
Performing Database Backup...
Backup Finished.
View /tmp/db_backup.out for details.
3.
List the contents of the fms/dbunload directory to verify the export.exp file is present and the creation date is expected.
hostname[netboss]/app/netboss/misc% cd $ANMDIR/fms/dbunload
hostname[netboss]/u01/app/netboss/fms/dbunload% ls –l
total 27168
-rw-r--r-- 1 netboss netboss 13900800 Sep 17 00:30 export.exp
Attachments