Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1957450.1
Update Date:2017-06-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1957450.1 :   Procedure For EMS Backup  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Goal
Solution


Created from <SR 3-9993631211>

Applies to:

Oracle Communications EAGLE (Software) - Version EMS 43.x to EMS 43.x [Release EMS 43.0]
Information in this document applies to any platform.

Goal

This document describes the steps to perform an EMS backup.
 

Solution

EMS BACKUP PROCEDURE & VERIFICATION


Establish an SSH connection and login to EMS Server as “netboss”

login as: netboss
Using keyboard-interactive authentication.
Password:
Last login: Thu May 22 13:03:36 2008 from 10.##.#.##
Sun Microsystems Inc. SunOS 5.10 Generic January 2005
You have new mail.
Use Default Display: << localhost:11.0 >> (y/n) ? y
DISPLAY set to localhost:11.0
Do you wish to start the NetBoss menu ( y or n )? N
hostname[netboss]/opt/home/netboss%

2.

Issue the commands to export the contents of the Netboss database to the $ANMDIR/fms/dbunload/export.exp file
hostname[netboss]/app/netboss/misc% $ANMDIR/misc/db_backup

Performing Database Backup...
Backup Finished.
View /tmp/db_backup.out for details.

3.

List the contents of the fms/dbunload directory to verify the export.exp file is present and the creation date is expected.
hostname[netboss]/app/netboss/misc% cd $ANMDIR/fms/dbunload
hostname[netboss]/u01/app/netboss/fms/dbunload% ls –l
total 27168
-rw-r--r-- 1 netboss netboss 13900800 Sep 17 00:30 export.exp
 