Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1956879.1
Update Date:2017-11-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1956879.1 :   How to Replace a SPARC T7-2 SAS HDD or SSD [VCAP]  


Related Items
  • SPARC T7-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution
References


Applies to:

SPARC T7-2 - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a SPARC T7-2 SAS HDD or SSD

Solution



 

***************************************************************************************
To report errors or request improvements on this procedure, please Add a comment on Doc ID: 1956879.1
***************************************************************************************

ESD Caution:

  • Circuit boards and drives contain electronic components that are extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these boards. Do not touch the components along their connector edges.
  • Use a Antistatic Wrist strap. Attach one end of the strap to your wrist and the other end to the chassis, depending on what type of strap you use, with the adhesive end or the metal plug.
  • Use an Antistatic Mat. Place ESD-sensitive components such as motherboards, memory, and other PCBs on an antistatic mat.

Contamination Caution:

  • Dust particles of packaging material are number one cause of datacenter contamination. Make sure to remove all packaging material, up to the ESD safe packaging material, while still being outside the datacenter.

 

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?:  No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: SPARC T7-2 SAS HDD or SSD Replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.


NOTE: This is a hot service procedure that can be performed by customers while the server is running. The drive must be taken offline before it is removed. If it cannot be taken offline, the OS must be shut down to prevent running programs from attempting to use it.

NOTE: Please be aware that disks could be in hardware raid volumes. The "cfgadm" commands shown in this document (and in the Service manual) are for individual drives that are not part of RAID volumes. When a drive is part of a RAID volume, you do not need to unconfigure it before swapping it with a new drive. When replacing a failed drive in a hardware RAID volume, follow the T7-2 RAID Drive Replacement Strategies at: http://docs.oracle.com/cd/E54983_01/html/E55000/z400086d1535370.html#scrolltoc

If the system is still up and functioning, the customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system. A data backup is not a prerequisite but is a wise precaution.
NOTE: For ALL scenarios where an AC power down or AC power cycle is required for a T7-x server, please always use the steps in doc 1571054.1 prior to physically removing AC power cables from the server.

 


WHAT ACTIONS ARE REQUIRED?:

Hard Drive Slot Configuration Reference
This topic describes the server’s hard drive slot organization.

This links shows the hard drive slot configuration: http://docs.oracle.com/cd/E54983_01/html/E55000/z400006b1564154.html#scrolltoc

Address mapping between the Oracle Solaris OS device paths and physical hard drive slots is not fixed. For many storage administration tasks, the mapping of OS device names to physical hard drive slots must be determined before the task can be performed. See the SPARC T7 series servers administration guide for information on mapping SAS controller ports to physical drive slots.

NOTE: The server requires at least one hard drive to be installed and operational.

NOTE: This is a hot service procedure that can be performed by Customers while the server is running.

CAUTION: The drive must be taken offline before it is removed. If it cannot be taken offline, the OS must be shut down to prevent running programs from attempting to use it.

* Determine if you need to shut down the OS to replace the drive, and perform one of the following actions:

1. If the drive cannot be taken offline without shutting down the OS, you'll have to power down the system before taking the drive offline.

2. If the drive can be taken offline without shutting down the OS, take the drive offline following this procedure:

http://docs.oracle.com/cd/E54983_01/html/E54987/z4001fde1390126.html#scrolltoc

- At the Oracle Solaris prompt, type the "cfgadm -al" command to list all drives in the device tree, including drives that are not configured.

- Select the drive that you want to remove. Unconfigure the drive using the "cfgadm -c unconfigure" command.

- Verify that the drives blue Ready-to-Remove LED is lit.
* Press the drive release button to unlock the drive and pull on the latch to remove the drive.
* Install the replacement drive or a filler tray.
* With the latch open on the replacement drive, align insert the drive into the drive bay and slide it forward until it is seated.
* Close the latch to lock the drive in place.
* Bring the drive online.
* Configure the drive using the cfgadm -c configure command.
* Verify the drive.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Verify functionality, no service LEDs or error messages. Reconfigure disk as previously configured. e.g. Part of raid volume set or mounted file-system or raw partition or other. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

SPARC T7-2 Server Service Manual https://support.oracle.com/handbook_private/Systems/SPARC_T7_2/components.html#Disks


REFERENCE INFORMATION:

SPARC T7-2 Server Service Manual http://docs.oracle.com/cd/E54983_01/html/E54987/index.html

Identifying the location of a failed Internal disk: How to locate a failed internal disk drive on a T3/T4/T5/T7 series system (Doc ID 1365089.1)

MPXIO Instructions can be found in these docs:
How to Identify Internal Disk Slot Numbers Using the mpathadm Utility on T3/T4 systems (Doc ID 1507646.1)
How to Identify the Target ID for an Internal System Disk under MPXIO/scsi_vhci Control (Doc ID 1542744.1)


Oracle Integrated Lights Out Manager 3.2 Documentation
http://docs.oracle.com/cd/E37444_01/

Detailed SVM instructions can be found at  http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html.
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions

Save

Save

References

<NOTE:1571054.1> - Performing an AC power cycle on the T3/T4/T5/S7/T7/T8 Servers

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback