Asset ID: |
1-71-1956446.1 |
Update Date: | 2016-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1956446.1
:
STP Measurements Unavailable Under NETBOSS Server
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
|
In this Document
Created from <SR 3-9708533281>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 42.x and later
Information in this document applies to any platform.
Goal
STP measurements unavailable under NETBOSS server. STP was not sending any reports to EMS server.
Solution
The collect parameter is OFF (shared log below). This should be turned ON in order to Eagle STP to start sending reports.
Execute following command to turn collect parameter ON.
>chg-meas:collect=on
Relevant log
============================
rtrv-meas-sched
stp 14-12-05 15:01:49 EST EAGLE5 42.0.1-63.38.31
rtrv-meas-sched
Command entered at terminal #34.
;
Command Accepted - Processing
stp 14-12-05 15:01:49 EST EAGLE5 42.0.1-63.38.31
COLLECT = off
GTWYLSFLTR = (both)
---------------------
SYSTOT-STP = (off)
SYSTOT-TT = (off)
SYSTOT-STPLAN = (off)
COMP-LNKSET = (off)
COMP-LINK = (off)
GTWY-STP = (off)
GTWY-LNKSET = (off)
MTCD-STP = (on)
MTCD-LINK = (on)
MTCD-STPLAN = (on)
MTCD-LNKSET = (on)
Attachments
This solution has no attachment