Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1956446.1
Update Date:2016-03-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1956446.1 :   STP Measurements Unavailable Under NETBOSS Server  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Goal
Solution


Created from <SR 3-9708533281>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 42.x and later
Information in this document applies to any platform.

Goal

STP measurements unavailable under NETBOSS server. STP was not sending any reports to EMS server.
 

Solution

The collect parameter is OFF (shared log below). This should be turned ON in order to Eagle STP to start sending reports.
Execute following command to turn collect parameter ON.
 
>chg-meas:collect=on
 
 
Relevant log
============================
rtrv-meas-sched
 
  stp 14-12-05 15:01:49 EST EAGLE5 42.0.1-63.38.31
  rtrv-meas-sched
  Command entered at terminal #34.
;
 
Command Accepted - Processing
  stp 14-12-05 15:01:49 EST EAGLE5 42.0.1-63.38.31
  COLLECT = off
  GTWYLSFLTR = (both)
  ---------------------
  SYSTOT-STP = (off)
  SYSTOT-TT = (off)
  SYSTOT-STPLAN = (off)
  COMP-LNKSET = (off)
  COMP-LINK = (off)
  GTWY-STP = (off)
  GTWY-LNKSET = (off)
  MTCD-STP = (on)
  MTCD-LINK = (on)
  MTCD-STPLAN = (on)
  MTCD-LNKSET = (on)
 