Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1955478.1
Update Date:2017-08-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  1955478.1 :   SL3000 - How to Verify Power is Available to CAPs (Cartridge Access Port)  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Verify Power is Available to CAPs (Cartridge Access Port).

Solution

Power to the CAPs is divided between left and right sides. Two LEDs on the PUW indicate whether power is available for each side. The split view show below is that of the PUW card as depicted from the rear of the card. Normally, service personnel would be looking at these LEDs from the other direction.

 PUW LEDs

The two LEDs indicate the status of three fused 48V connections on J319. If the CAPs/PUZ have no power, this is a way of verifying that the fuse is good. One for the left side and one for the right side CAPs.

Fuse Status