![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1955478.1 : SL3000 - How to Verify Power is Available to CAPs (Cartridge Access Port)
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. GoalHow to Verify Power is Available to CAPs (Cartridge Access Port). SolutionPower to the CAPs is divided between left and right sides. Two LEDs on the PUW indicate whether power is available for each side. The split view show below is that of the PUW card as depicted from the rear of the card. Normally, service personnel would be looking at these LEDs from the other direction. The two LEDs indicate the status of three fused 48V connections on J319. If the CAPs/PUZ have no power, this is a way of verifying that the fuse is good. One for the left side and one for the right side CAPs. Attachments This solution has no attachment |
||||||||||||||
|