Solution Type  Technical Instruction Sure

Solution  1954413.1 :   EMS /var Directory is Fully Utilized. Root and Netboss Mails are Taking Up Too Much Space  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-9847282511>

Applies to:

Oracle Communications EAGLE (Software) - Version EMS 43.x to EMS 44.x [Release EMS 43.0 to EMS 44.0]
Tekelec

Goal

/var directory is 100% utilized

Solution

Enter: df -hk

If 100% utilization is observed, Perform the following steps:

cd /var/mail

ls -al

 

If file named netboss or root are in GBs

Zip the file:

To zip a file named "netboss" in directory /var/mail

zip -r /var/mail/netboss.zip netboss


To clean mails from /var/mail/netboss  
login as root user:
# > /var/mail/netboss

# > /var/mail/root 