| Asset ID: |
1-71-1953578.1 |
| Update Date: | 2018-01-05 |
| Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1953578.1
:
Oracle ZFS Storage Appliance: (SuperCluster) 7320 ILOM not Pingable
| Related Items |
- Oracle SuperCluster T5-8 Full Rack
|
| Related Categories |
- PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
- Tools>Primary Use>Configuration
|
ZFS Storage appliance ILOM interface is not pingable
Created from <SR 3-9987782620>
Applies to:
Oracle SuperCluster T5-8 Full Rack - Version All Versions and later
7000 Appliance OS (Fishworks)
Goal
ILOM IP address is not pingable.
Solution
In supercluster, the ILOMs are configured to redirected side-band management through NET0 and therefore no cable is connected to it.
See Bug 15760846 CONFIG. WORK./SITE CHECKLIST - ZFS MANAGEMENT NETWORK DESCRIPTION).
The ILOM management port needs to be set to /SYS/MB/NET0 as below
-> show network
/SP/network
Targets:
interconnect
ipv6
test
Properties:
commitpending = (Cannot show property)
dhcp_server_ip = none
ipaddress = x.x.x.x
ipdiscovery = static
ipgateway = x.x.x.x
ipnetmask = x.x.x.x
macaddress = aa:bb:cc:dd:ee:ff
managementport = /SYS/MB/NET0
outofbandmacaddress = aa:bb:cc:dd:ee:ff
pendingipaddress = x.x.x.x
pendingipdiscovery = static
pendingipgateway = x.x.x.x
pendingipnetmask = x.x.x.x
pendingmanagementport = /SYS/SP/NET0
sidebandmacaddress = aa:bb:cc:dd:ee:ff
state = enabled
Attachments
This solution has no attachment