![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1951879.1 : IBM LTO5 - Belisarius Card Firmware Update Using VOP (Virtual Op Panel)
In this Document
Applies to:IBM LTO5 Tape Drive - Version All Versions and laterIBM LTO4 Tape Drive - Version All Versions and later IBM LTO6 Tape Drive - Version All Versions and later Information in this document applies to any platform. GoalHow to update Belisarius card firmware on IBM LTO4/5/6 drives in SL500/3000/8500 libraries. Solution1. Download latest Belcode to the laptop being used. (current: 4.17.18.36 MOS Patch: 145727-06) http://tape.us.oracle.com/pmwiki/index.php?n=Main.BelisariusHistory 2. Install LTO VOP on your laptop (Install CSE Multi drive VOP 2.2 from SAC). 3. Connect to the Drive tray Encryption port(defaul IP 10.0.0.1). 4. Go to the 'service drive' tab for code update. 5. Click the "Load 4.x firmware" icon. Follow the attached PDF for further details.
Attachments This solution has no attachment |
||||||||||||||
|