Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1951859.1
Update Date:2016-05-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1951859.1 :   Which Performance Intelligence Center (PIC) 10.1.0 Patches to Update and How to Install Them ?  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Goal
Solution
 XMF
 IXP
 xDR Builders
 NSP
 Link to PIC 10.1.0 documentations
References


Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.0 to 10.1.0 [Release 10.0]
Information in this document applies to any platform.

Goal

Patch files to install on a PIC 10.1.0 system:

 Patch filesBugs fixed
XMF 23146958 includes
complete iso of xMF 10.1.0-7.7.0
19987036 - Way Management is not applied on MSUs
20017407 - pmiaMonitor process crash
20796767 - UDP fragmented frames missing in xDR
22616859 - ISUP RLC MSUs on M3UA Links with Eagle STC copy are lost
IXP 20161371 includes
TKLCixp-10.1.0-7.4.0.x86_64.rpm
TKLCplatixp-10.1.0-7.4.0.noarch.rpm
TKLCixpdb-10.1.0-7.4.0.x86_64.rpm
TKLCixputils-10.1.0-7.4.0.x86_64.rpm
20066535 - IxpBuild restarts in loop when reconfigured or when manually restarted
xDR Builders 20994256 includes
xDR builder package 10.1.0-7.30.0 

20330016 - LteS1ap Performance Enhancement
20325732 - Mobile Database inactivity can't be increased over one day
20357394 - GTPv2: Some messages are filtered by LTE GTPv2 decoding layer
20468024 - Crashing issue on LTE GTPv2 builder
20882296 - LIDB TDR is missing GetData in LIDBOperation field
19604121 - Diameter Gy not decoded 

NSP 21560337 includes
complete iso of NSP 10.1.0-7.5.0

19930955 - GASSI Users do not see any objects
19948593 - Only one DWS of the pool is queried by CalculateAllSessionPeriod
19948557 - Start date and end date are not refreshing in ProTrace after upgrade
20068879 - KPI drill down from ProAlarm Viewer to Protrace isn't filtering on line
20171902 - No Time displayed on the ProPerf dashboard when you click on the curves

Installing patches above ensures all latests fixes available are implemented.

Solution

Installation instructions for each component:

XMF

Use incremental upgrade documentation (link in reference below) or contact support for instructions.

IXP

This patch is to apply on IXP 10.1.0-6.2.0 only.
All the following steps have to be run as root user.
PIC10.1.0 Patch2 includes fixes of PIC10.1.0 Patch1
  1. Copy the files of the patch on each server of the IXP subsystem. As root:
    1. create the directory /var/TKLC/upgrade/20066535
    2. copy the files into /var/TKLC/upgrade/20066535
    3. be sure the files have root right accesses
  2. Upgrade each server of the IXP subsystem, one after the other, as follows. As root, run:
    # service TKLCixp stop
    # cd /var/TKLC/upgrade/20066535
    # rpm -Uvh *.rpm
    # service TKLCixp start

xDR Builders

Use incremental upgrade documentation (link in reference below) or contact support for instructions.

NSP

Use incremental upgrade documentation (link in reference below) or contact support for instructions.

Link to PIC 10.1.0 documentations

https://docs.oracle.com/cd/E56061_01/index.htm

References

<BUG:19987036> - WAY MANAGEMENT IS NOT APPLIED ON MSUS
<BUG:20017407> - PMIAMONITOR PROCESS CRASH
<BUG:20796767> - UDP FRAGMENTED FRAMES MISSING IN XDR
<BUG:20066535> - IXPBUILD RESTARTS IN LOOP WHEN RECONFIGURED OR WHEN MANUALLY RESTARTED
<BUG:20330016> - S1-AP PERFORMANCE ENHANCEMENT
<BUG:20325732> - MOBILE DATABASE INACTIVITY CAN'T BE INCREASED OVER ONE DAY.
<BUG:20357394> - GTPV2: SOME MESSAGES ARE FILTERED BY LTE GTPV2 DECODING LAYER
<BUG:20468024> - GTPV2 BUILDER IS CRASHING
<BUG:20171902> - NO TIME DISPLAYED ON THE PROPERF DASHBOARD WHEN YOU CLICK ON THE CURVES
<BUG:20068879> - KPI DRILL DOWN FROM PROALARM VIEWER TO PROTRACE ISN'T FILTERING ON LINE
<BUG:20882296> - LIDB TDR IS MISSING GETDATA IN LIDBOPERATION FIELD
<BUG:19604121> - DIAMETER GY NOT DECODED
<BUG:20161371> - PATCH FOR PIC 10.1
<BUG:22616859> - ISUP RLC MSUS ON M3UA LINKS WITH EAGLE STC COPY ARE LOST