In this Document
Goal
Solution


Applies to:

Sun Netra 210 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 Netra 210 - How to Remove and Replace Netra 240 SAS IF Assemble or Disk Backplane Assembly

Solution

DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED

No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 50 mins

TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:


PROBLEM OVERVIEW: Disk Backplane failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTIONS ARE REQUIRED:

Removing the SAS IF Assembly (Disk Backplane)

1. Power off the server, remove the server from the rack, open the bezel, and remove the top cover and airduct.
2. Locate the SAS IF assembly (disk backplane). The SAS IF assembly is located at the right front of the chassis.
3. Remove the hard drives.
4. Disconnect the cables from the SAS IF assembly in this order:
■ The cable from the DVD assembly at J5
■ The cable from the power supply at J501
■ The two SAS cables at J7

5. Using a No. 2 Phillips screwdriver, loosen the two screws that secure the SAS IF assembly to the chassis.

6. Lift the SAS IF assembly straight up and out of the chassis.

7. Set the SAS IF assembly aside on an antistatic mat.
Caution – Do not power on the server without the SAS IF assembly installed.

8. Determine your next steps:
■ If you were directed here by another procedure, return to that procedure.

■ Otherwise, replace the SAS IF assembly.

Installing the SAS IF Assembly (Disk Backplane)

1. Remove the server from the rack, open the bezel, and remove the top cover and airduct.

2. Locate where the SAS IF assembly installs. The SAS IF assembly installs at the right front of the chassis.

3. Remove the replacement SAS IF assembly from its shipping container and antistatic packaging.

4. Lower the SAS IF assembly into position.

5. Using the No. 2 Phillips screw driver, tighten the two screws to secure the SAS IF
assembly to the chassis.

6. Connect the cables to the SAS IF assembly in this order:
■ The two SAS cables at J7
■ The cable from the power supply at J501
■ The cable from the DVD assembly at J5

7. Install the hard drives.

8. Determine your next steps:
■ If you were directed here by another procedure, return to that procedure.
■ Otherwise, install the air duct and top cover, close the bezel, install the server into the rack, power on the server, and verify the installation.

OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

Bring system back up to a functioning state.
Restart software applications per applicable administration guides to resume system operation.