Instructions on how to replace a Pilot Battery in an FS1-2.

In this Document
Goal
Solution
References


Applies to:

Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]
Oracle FS1-2 Cloud System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

The purpose of this document is to outline the steps required to replace an FS1-2 Pilot Battery using the Guided Maintenance.

Solution

DISPATCH INSTRUCTIONS

- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:

Product knowledge, FS1-2 Flash Storage System

TIME ESTIMATE: 45 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW:

What: A Pilot Battery in an FS1-2 has failed and needs to be replaced.

Where: There will be a System Alert that identifies the problem Pilot with the failed Battery. 

Why: An FS1-2 Pilot Battery has failed.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?

The Pilot with the Battery failure will have a warning status.  The other Pilot must have a normal status as this procedure requires a Pilot failover if the problem is detected on the current active Pilot.  The problem Pilot must be powered off in order to replace the failed Battery.

 

NOTE: Please review the Knowledge <Document 1942676.1> FS System: How to Disable Call-Home to Prevent Automatic Service Request (ASR) Generation before proceeding with the procedure below. The steps contained therein are provided to allow an Administrator to de-activate a particular ASR enabled array while performing maintenance or troubleshooting. This will prevent any additional Service Requests from being created unnecessarily.

QRC for this procedure:

Pilot Battery QRC

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:

  1. Prepare the FS1-2 for service procedure.
    1. Disable Call-Home to prevent spurious alerts (see Document 1942676.1 FS System: How to Disable Call-Home to Prevent Automatic Service Request (ASR) Generation).
    2. Use ESD precautions.
    3. Log into Oracle FS System Manager to access Guided Maintenance:
      1. Select System tab
      2. In the navigation tree, expand Hardware and select Pilots
      3. In the main window, right click on the Pilot with the failed Battery and select Repair Pilot.
      4. In the pop-up Pilot Repair window, select Battery from the pull-down menu and the click on Next.
      5. Follow the steps in Guided Maintenance to identify and place the Pilot offline.

  2. Access the Battery.
    1. Deploy the anti-tip legs in the front of the rack.
    2. Slide the Pilot into the service position.
    3. Unplug both power cords.
    4. Open the Fan door to make top cover removal easier.
    5. Slide the Top Cover back and remove.

  3. Remove the Battery.
    1. The Battery is located on the rear side of CPU 0.
    2. Remove the failed Battery by placing your finger under the side of the Battery nearest the rear of the server and gently lift it out.
      NOTE: If the Pilot is an X5-2 version, check to see if an Oracle System Assistant (OSA) USB drive is installed internally on the Pilot motherboard.  If one is installed, proactively remove it.  While having the OSA USB drive installed does not affect day to day operations of the FS1-2, it will create problems if the Pilot needs to be re-imaged in the future.
       
  4. Install the replacement Battery.
    1. Press the replacement Battery into the retainer with the + side facing up.
    2. Close the Top Cover.
    3. Close Fan door.

  5. Return the Pilot to the FS1-2
    1. Plug in both power cords.
    2. Return the Pilot to the rack position.
    3. Return the anti-tip legs to their normal position.
    4. When finished, re-enable Call-Home.


OBTAIN CUSTOMER ACCEPTANCE


WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

 Confirm that the replacement Battery was successful - the System Alert associated with it should be gone and the FS1-2 should be normal/green.

Note: because the Pilot must cold start, it may take as long as 10 minutes for the boot process to complete and the Pilot to return to a normal status.

REFERENCE INFORMATION:

From the Oracle Help Center: http://docs.oracle.com/en/storage/#fla select the Oracle Flash System Documentation Library for more information.

 

 

 

 