Solution Type  Technical Instruction Sure

Solution  1946291.1 :   Dataexport cannot Mount the NFS Shared Directory from Export Server  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Goal
Solution
References


Created from <SR 3-9884730081>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.4 and later
Tekelec

Goal

Why dataexport process is not able to mount nfs share with error permission denied ?

Solution

Because server hostname is not matching /etc/exports rules file on export server and/or /etc/hosts does not contain host/ip of dataexport server.

References

<NOTE:1993282.1> - What is the Necessary Configuration to Make Sure DataExport will be Able to Send Files to the Export Server ?