Asset ID: |
1-71-1946291.1 |
Update Date: | 2017-06-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1946291.1
:
Dataexport cannot Mount the NFS Shared Directory from Export Server
Related Items |
- Oracle Communications Performance Intelligence Center (PIC) Software
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
|
In this Document
Created from <SR 3-9884730081>
Applies to:
Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.4 and later
Tekelec
Goal
Why dataexport process is not able to mount nfs share with error permission denied ?
Solution
Because server hostname is not matching /etc/exports rules file on export server and/or /etc/hosts does not contain host/ip of dataexport server.
References
<NOTE:1993282.1> - What is the Necessary Configuration to Make Sure DataExport will be Able to Send Files to the Export Server ?
Attachments