Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1942590.1
Update Date:2017-06-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  1942590.1 :   How do we change the default route on Infiniband switches  


Related Items
  • Sun Datacenter InfiniBand Switch 36
  •  
  • Sun Datacenter InfiniBand Switch 648
  •  
  • Sun Datacenter InfiniBand Switch 72
  •  
  • Sun Network QDR InfiniBand Gateway Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Goal
Solution


Created from <SR 3-9755402353>

Applies to:

Sun Datacenter InfiniBand Switch 648 - Version All Versions and later
Sun Datacenter InfiniBand Switch 72 - Version All Versions and later
Sun Datacenter InfiniBand Switch 36 - Version All Versions and later
Sun Network QDR InfiniBand Gateway Switch - Version All Versions and later
Information in this document applies to any platform.

Goal

 This document explains how the default route on Infiniband Switches can be changed.

Solution

The steps below can be used to set the management ip address and its default router in Infiniband switches (nm2-36p, nm2-gw, infiniband switch 72 )

This is set in the ILOM.. Do not edit any of the etc files from the Linux CLI.

Here is an example:

Login to ilom of the switch.  Then,
Configure the Switch management network settings:
-> cd /SP/network
-> set pendingipaddress=10.196.16.152
-> set pendingipgateway=10.196.23.254
-> set pendingipnetmask=255.255.248.0
-> set pendingipdiscovery=static
-> set commitpending=true

 