Goal
Replace HP server controller card battery.
Solution
High level step to follow during Controller card Battery replacments.
- Onsite support is required to complete this activity.
- The onsite person requires no hardware-specific training to replace the defective part. But should have familiarity with system hardware and software requiring repair.
- Power down the server
- Remove the server from rack/blade
- Remove the access panel
- Disconnect the BBWC cable from the cache module(For Blade servers only). In the case of rack mount servers disassemble the Controller card and replace the batteries(Child and Parent batteries).
- Replace the battery pack (Connect the BBWC cable from the cache module for Blade servers CAUTION: To prevent damage to the cache module during installation, be sure the cache module is correctly inserted before pressing down)
- Replace the battery pack (For rack mount servers put back the controller card with new batteries).
- Place the access panel and put the server blade back
- Power up the server
Once the server is up, do a heath check by giving following command if you have the login credentials.
As root:
>syscheck
>hpacucli ctrl all show status
Battery may take time to fully charge.