Asset ID: |
1-71-1940572.1 |
Update Date: | 2014-11-04 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1940572.1
:
Oracle Key Manager (OKM) - Restore of Backup File Times Out With Error: "end of file or no input: operation interrupted or timed out (15 S receive delay) (15 S send delay)"
Related Categories |
- PLA-Support>Sun Systems>TAPE>Backup Software-Filesystems>SN-TP: Encryption
|
In this Document
Created from <SR 3-9793129641>
Applies to:
Oracle Key Manager - Version 2.0.0 to 3.0 [Release 2.0 to 3.0]
Information in this document applies to any platform.
Goal
During restore of OKM backup files to a newly initialized KMA server at a DR site, the restore process times out with these error messages:
--
Upload Backup Fail Failed
Error: end of file or no input: operation interrupted or timed out (15 S receive delay) (15 S send delay)
--
The backup file size is 85MB.
Is there a configuration parameter in OKM that can extend the timeout period over 15 seconds?
Solution
On the OKM GUI System tab, select Options.
An Options window will pop up and accepts a "Communication Timeout" value from 1 thru 300 seconds.
( The maximum timeout value in earlier versions of OKM is 60 seconds with a default of 15 seconds. )
Attachments