Solution  1938721.1 :   SL8500 - How to Reset a SL8500 D-Link WebCam  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


If IP address and or password of WebCam user has been lost or forgotten

In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: clarify reset to manufacturing setting of D-Link WebCam
Created from <SR 3-9771663939>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Reset D-Link WebCam, return to manufacturing settings.

Goal

On going problems with D-Link IP cameras build into SL8500 libraries.

Upon reviewing the history it turned out that one camera in each library had been replaced.
 

Solution

WebCams will need to be hard reset to manufacture settings and re-installed newly.

WebCams are of model D-Link DCS 5300.

Reset and Restore:

There is a button hidden in the pinhole beside the Ethernet socket. It is used to reset the system or restore the factory default settings. Sometimes resetting the DCS-5300 will return the system back to a normal state. If the system still has problems after reset, restore the factory settings and install again:

Reset:

1. Lightly insert a paper clip (or a similar sized tool) into the reset hole on the back of the camera, press lightly and then release the button.

2. The LED on the front of the camera will begin blinking red and green.

3. When the LED stops the blinking the reset has completed.

Restore:

1. Insert the paperclip or other tool and press on the button continuously.

2. Wait for the LED on the front of the camera to blink red and green and hold the button through two cycles of blinking (about 5-7 seconds.)

3. Withdraw the tool after the second cycle of the LED blinking and a factory restore has been completed.

 

(NOTE:This procedure can be found in attached document page 129)

References

<NOTE:1485887.1> - How to Remove / Replace a IP Camera in a SL8500

Attachments