All four Brocade switches are showing as subordinate
Related Categories |
- PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
|
In this Document
Created from <SR 3-9712645511>
Applies to:
Brocade 300 Switch - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
All 4 Brocade switches are showing as subordinate.
Solution
Execute the following to make core switch the principal switch.
set your core switch to be fabricprincipal
fabricprincipal 1
set your edge switches not to be fabricprincipal
fabricprincipal 0
Then force a fabricrebuild on the core switch, WARNING THIS IS DISRUPTIVE ACTION !!
fabricprincipal -f 1