Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1931958.1
Update Date:2016-08-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1931958.1 :   VLE 1.2 Mode Descriptions  


Related Items
  • Sun StorageTek Enterprise Library Software (ELS)
  •  
  • Sun Virtual Library Extension (VLE)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Library Software>SN-TP: MAINSW VTCS
  •  




In this Document
Goal
Solution


Created from <SR 3-9656703421>

Applies to:

Sun StorageTek Enterprise Library Software (ELS) - Version 7.1 and later
Sun Virtual Library Extension (VLE) - Version 1.2 and later
IBM z/OS on System z

Goal

VLE Configuring the MVS Host Software for VLE 1.2 manual shows three modes: Toleration, Exploitation and Acceleration
Please explain the three modes listed in the VLE 1.2 manual titled VLE Configuring the MVS Host Software for VLE 1.2.
 

Solution

Toleration - The VLE supports VLE to VLE copy and multiple nodes but VTCS does not. (e.g. you have a VLE 1.1 or 1.2 but don't have the support PTFs)
Exploitation - VTCS supports VLE to VLE copy and multiple nodes. It tries to balance MVC storage allocation across the nodes and uses a VLE for sourcing VTV copies for migrates.
Acceleration - ADS mode is switched on in VTCS. Hence more concurrent migrates are possible. This is only possible in ELS V7.1.

Note that with VLE 1.3 and higher the Toleration, Exploitation, Acceleration mode terminology has been removed and only 2 modes are supported:

CONFIG TAPEPLEX STORMNGR (formerly known as Toleration mode)
and
CONFIG STORMNGR statement with the VLEDEV parameter (formerly known as Acceleration mode)
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback