Asset ID: |
1-71-1931055.1 |
Update Date: | 2017-02-15 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1931055.1
:
IPTPS Peak Value Abnormal After Health Check (HC) 2 Activity
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
|
In this Document
Created from <SR 3-9658183336>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 44.x and later
Tekelec
Goal
MAXSLKTPS value shows too high during HC2 for some linksets.
For example:
IP TPS USAGE REPORT
THRESH CONFIG/ CONFIG/ TPS PEAK PEAKTIMESTAMP
RSVD MAX
--------------------------------------------------------------------------
LSN
mshtb 80% 4000* 26000 TX: 2310 2897 14-09-27 19:07:36
RCV: 2330 286331153 14-09-23 06:00:06
--------------------------------------------------------------------------
LOC LINK
1201 A 80% 500* 5000 TX: 294 370 14-09-27 19:07:36
RCV: 287 355 14-09-27 19:07:36
1203 B 80% 500* 5000 TX: 306 4294901760 00-00-00 00:00:00
RCV: 288 366 14-09-27 19:07:36
1301 A 80% 500* 5000 TX: 267 16776960 00-00-00 00:00:00
RCV: 286 361 14-09-27 19:07:36
Solution
This is related to PR 221429
REPT-STAT-IPTPS reports a wrong (higher) total MAXTPS for the IPSG linkset if following 2 conditions are true
1) more than 1 links of a IPSG linkset configured on a single ENET-A card
2) the multiple of MAXSLKTPS configured for the IPSG linkset and the number of its links of the on a single ENET-A card is more than 5000
Resolution has been tested in Eagle: 45.0.0-64.50.0
From the commands shared; I take example of mshtb:
> rept-stat-iptps:lsn=mshtb
stpabc 14-09-29 14:07:01 EST EAGLE5 44.0.4-64.34.24
rept-stat-iptps:lsn=mshtb
Command entered at terminal #17.
;
Command Accepted - Processing
stpabc 14-09-29 14:07:01 EST EAGLE5 44.0.4-64.34.24
IP TPS USAGE REPORT
THRESH CONFIG/ CONFIG/ TPS PEAK PEAKTIMESTAMP
RSVD MAX
--------------------------------------------------------------------------
LSN
mshtb 80% 4000* 26000 TX: 2310 2897 14-09-27 19:07:36
RCV: 2330 286331153 14-09-23 06:00:06
--------------------------------------------------------------------------
LOC LINK
1201 A 80% 500* 5000 TX: 294 370 14-09-27 19:07:36
RCV: 287 355 14-09-27 19:07:36
1203 B 80% 500* 5000 TX: 306 4294901760 00-00-00 00:00:00
RCV: 288 366 14-09-27 19:07:36
1301 A 80% 500* 5000 TX: 267 16776960 00-00-00 00:00:00
RCV: 286 361 14-09-27 19:07:36
1303 B 80% 500* 5000 TX: 273 352 14-09-27 19:07:36
RCV: 290 362 14-09-27 19:07:36
1201 B 80% 500* 5000 TX: 303 374 14-09-27 19:07:36
RCV: 297 364 14-09-27 19:07:36
1203 A1 80% 500* 5000 TX: 309 375 14-09-27 19:07:36
RCV: 294 361 14-09-27 19:07:36
1301 B 80% 500* 5000 TX: 277 353 14-09-27 19:07:36
RCV: 298 360 14-09-27 19:07:36
1303 A1 80% 500* 5000 TX: 279 341 14-09-27 19:07:36
RCV: 285 357 14-09-27 19:07:36
--------------------------------------------------------------------------
Command Completed.
;
Command Executed
> rtrv-bip:loc=1203
stpabc 14-09-29 14:11:41 EST EAGLE5 44.0.4-64.34.24
rtrv-bip:loc=1203
Command entered at terminal #17.
;
Command Accepted - Processing
stpabc 14-09-29 14:11:41 EST EAGLE5 44.0.4-64.34.24
--------------------------------------------------------------------------
Location: 1203 - MBD
Part Number: 870-2212-05
Revision: H Week/Year: 44/2010
Serial Number: 10210447###
Software Match ID: EG - 001 Max Power Rating : 646mA
--------------------------------------------------------------------------
END OF REPORT
;
Command Executed
The linkset has more than one link on card 1203. Which is E5ENT-A card.
Hence the PR is being hit.
Please contact Support for more details on the PR
Attachments
This solution has no attachment