Solution Type  Technical Instruction Sure

Solution  1925683.1 :   Brocade: ErrDump Reporting c3DiscardTo Errors Multiple Times Even After Clearing The Error Counters In The Switch  


Related Items
  • Brocade 300 Switch
  •  
  • Brocade 5300 Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  




In this Document
Goal
Solution


Created from <SR 3-9518530291>

Applies to:

Brocade 300 Switch - Version All Versions to All Versions [Release All Releases]
Brocade 5300 Switch - Version All Versions and later
Information in this document applies to any platform.

Goal

The errDump logs reported the following:

$ grep c3DiscardTo SSHOW_EX.txt
2014/05/01-22:01:36, [FW-1202], 444, FID 128, WARNING, switch01, host1_shba2, Port#1,c3DiscardTo, is above high boundary(High=10, Low=0). Current value is 150 Error(s)/minute.
2014/05/07-05:12:34, [FW-1202], 457, FID 128, WARNING, switch01, host1_shba2, Port#1,c3DiscardTo, is above high boundary(High=10, Low=0). Current value is 32 Error(s)/minute.
2014/06/22-02:04:56, [FW-1202], 480, FID 128, WARNING, switch01, host1_shba2, Port#1,c3DiscardTo, is above high boundary(High=10, Low=0). Current value is 90 Error(s)/minute.
2014/07/26-05:32:19, [FW-1202], 494, FID 128, WARNING, switch01, host1_shba2, Port#1,c3DiscardTo, is above high boundary(High=10, Low=0). Current value is 96 Error(s)/minute.
2014/08/14-03:09:13, [FW-1202], 501, FID 128, WARNING, switch01, host1_shba2, Port#1,c3DiscardTo, is above high boundary(High=10, Low=0). Current value is 168 Error(s)/minute.
2014/08/24-09:52:55, [FW-1202], 517, FID 128, WARNING, switch01, host1_shba2, Port#1,c3DiscardTo, is above high boundary(High=10, Low=0). Current value is 120 Error(s)/minute.
$

 

Solution


From the Brocade  FabOS Message Reference Manual:


FW-1202
Message              <Port Name> <Label>, is above high boundary(High=<High value>, Low=<Low value>).
                             Current value is <Value> <Unit>.

Message Type     AUDIT | LOG

Class                   FW

Severity               ERROR

Probable Cause  Indicates that the number of C3 transmit timeout frames is above the high threshold.

Recommended     Check the target device; it could be slow.
Action

 

See also: