Asset ID: |
1-71-1925394.1 |
Update Date: | 2016-02-19 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1925394.1
:
CAM - How to Remove and Replace Midrange Disk LCSM100 Drive Cage/Midplane
Related Items |
- Sun Storage 2510 Array
- Sun Storage 2540 Array
- Sun Storage 2530 Array
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
|
In this Document
Applies to:
Sun Storage 2530 Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 2540 Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to remove and replace Midrange Disk LCSM100 Drive Cage/Midplane using CAM
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Basic 2500/6000 Array Hardware Introduction.
Common Array Manager
TIME ESTIMATE: 90 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: LCSM100 Disk Tray Midplane has been identified as faulty.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Collect a support data from the array, prior to any action.
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:
NOTE: If ASR is enabled, it should be deactivated temporarily before servicing the equipment so that additional unnecessary Service Requests are not created.
DEACTIVATING ASR WITH CAM 6.10: ASR is automatically deactivated when you select "Reserve the tray for maintenance" in Service Advisor, and it is reactivated when you select "Release the tray from maintenance" in Service Advisor.
DEACTIVATING ASR WITH CAM 6.9 OR EARLIER: Before proceeding with the part replacement:
1. Log into CAM.
2. Go to "Storage Systems" -> [your arrayname] -> "Administration" -> "Array Health Monitoring".
3. Uncheck the box "Enable ASR for this array" under the section "Monitoring for This Array". If the box is already unchecked, there is no action required. Remember the status however, as it will matter in step 3 of REACTIVATING ASR WITH CAM 6.9 OR EARLIER below.
4. Click on "Save" if you have unchecked the box in step 3 above.
1. Ensure the customer has brought down all hosts attached to the array.
2. Log into CAM and open the service advisor. Under the "CRU Removal/Replacement Procedures" Section select "Tray Midplane Removal/Replacement" procedure.
3. Click on the tray requiring Midplane replacement, and follow the directions therein.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
1. Verify That no critical faults exist on the system
2. Verify That all drives in the affected tray can be seen in CAM
3. Verify all volumes are in an optimal state.
4. Customer should boot the hosts, and verify that the data can be accessed.
REACTIVATING ASR with CAM 6.10: ASR is automatically deactivated when you select "Reserve the tray for maintenance" in Service Advisor, and it is reactivated when you select "Release the tray from maintenance" in Service Advisor. If ASR was not enabled before beginning this procedure, selecting "Release the tray from maintenance" will not activate it.
REACTIVATING ASR WITH CAM 6.9 OR EARLIER: After proceeding with the part replacement:
1. Log into CAM.
2. Go to "Storage Systems" -> [your arrayname] -> "Administration" -> "Array Health Monitoring".
3. Check the box "Enable ASR for this array" under the section "Monitoring for This Array". Do this ONLY if you unchecked the box in step 3 of DEACTIVATING ASR WITH CAM 6.9 OR EARLIER. If you found the box was unchecked, leave it unchecked now.
4. Click on "Save" if you have checked the box to reactivate ASR.
PARTS NOTE:
REFERENCE INFORMATION: Reference the Service Advisor in CAM
NOTE: If the service advisor is not available, you may download or review a soft copy internally at: http://pts-storage.us.oracle.com/products/CAM/SA.html
Attachments
This solution has no attachment