![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1924371.1 : FS System: How to Remove and Replace Hard Disk Drive or Solid State Drive from an FS1-2 Drive Enclosure
Instructions on how to replace Drive Enclosure Hard Disk Drive or Solid State Drive. In this Document
Applies to:Oracle FS1-2 Cloud System - Version All Versions to All Versions [Release All Releases]Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalThe purpose of this document is to outline the steps required to replace an FS1-2 Hard Disk Drive or Solid State Drive using Guided Maintenance SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Product knowledge, FS1-2 Flash Storage System TIME ESTIMATE: 30 minutes TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: WHAT: A Drive Enclosure Hard Disk Drive (HDD) or Solid State Drive (SSD) in an FS1-2 has failed and needs to be replaced WHERE: FS1-2 Drive Enclosure location and Drive slot location should be in event log WHY: The Drive has failed. WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: All Drive Enclosure configurations include a Hot Spare drive which will take the place of the failed drive. If the FS1-2 is conducting a copy-away from a drive it suspects will fail soon, please wait until that process is completed before replacement.
NOTE: If the FS1-2 has a failed HDD and is running software below R6.1.18, please see Document 2051245.1 FS1-2 Drive Failures May Result in Data Loss if Controllers Warm Start or Boot During Rebuild or Copyback for additional instructions.
NOTE: The DE2-24C uses only 3.5" SAS drives and DE2-24P uses either SAS 2.5" or SSD 2.5" Drives
NOTE: Please use KM Document 1684888.1 How to Change the Mounting Bracket of a 1.6TB SSD Drive in an FS1-2 Drive Enclosure if the failed drive is an SSD with a capacity of 1.6TB.
NOTE: Please review the Knowledge Document 1942676.1 FS System: How to Disable Call Home to Prevent Automatic Service Request ASR Generation before proceeding with the procedure below. The steps contained therein are provided to allow an Administrator to de-activate a particular ASR enabled array while performing maintenance or troubleshooting. This will prevent any additional Service Requests from being created unnecessarily.
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: Confirm that replacement SSD is the new floating spare drive or that the HDD starts a copyback (HDDs have a "rotating" spare where "spare" rotates to the next HDD for each stripe). REFERENCE INFORMATION: From the Oracle Help Center: http://docs.oracle.com/en/storage/#fla select the Oracle Flash System Documentation Library for more information. References<BUG:22827582> - HIGH LATENCY DUE BACKGROUND TASKSAttachments This solution has no attachment |
||||||||||||||||
|