Goal

When creating a RAC database with oakcli create database -db RACabc -oh /u01/app/oracle/product/11.2.0.4/dbhome_1
I receive this message:

INFO : setting up ssh for user oracle...
.....ERROR: Error in authorized_keys, file has more than one line on node oda2-2 (see above text) at /opt/oracle/oak/onecmd/GridSteps.pm line 6361
 

Solution

The oracle user password on both the nodes are not the same.
 
Please check the password on both the nodes and make it same.
 