Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1923073.1
Update Date:2016-01-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1923073.1 :   How to Remove and Replace a PSU in a Sun StorageTek D240 Media Tray  


Related Items
  • Sun Storage D240 (StorEdge) Media Tray
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Sun Storage D240 (StorEdge) Media Tray - Version All Versions and later
Information in this document applies to any platform.

Goal

 How to Remove and Replace a PSU in a Sun StorageTek D240 Media Tray

Solution

DISPATCH INSTRUCTIONS
   WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Knowledge of the Sun StorageTek D240 Media Tray administration procedures
   TIME ESTIMATE: 30 mins
   TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
   PROBLEM OVERVIEW:
Power Supply has been determined as faulty and requires replacement

   WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:
The media tray can operate with only one functioning power supply.

   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Removing a power supply:
1. Disconnect the power cord from the faulty power supply assembly.
2. Loosen the two captive screws on the power supply.
3. Unlatch the handle from the purple snap catch and rotate the handle downwards 90 degrees. This releases the power supply from the main logic board.
4. Pull on the handle to remove the power supply.

Replacing a power supply:
1. Holding the handle, push the replacement power supply firmly into the chassis. The power supply connector slides into the chassis and mates smoothly with the main logic board connector. Physical damage to the power supply connector can result from the application of excessive force.
2. Rotate the handle upward 90 degrees and seat the power supply to the main logic board.
3. Latch the handle under the purple snap catch.
4. Tighten the two captive screws on the power supply.
5. Reconnect the power cord.

OBTAIN CUSTOMER ACCEPTANCE
   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Verify the fault has cleared.

PARTS NOTE: