Solution Type Technical Instruction Sure Solution 1920388.1 : L1400 - Router is Not Seeing the Robot
In this Document
Created from <SR 3-9474914121> Applies to:Sun StorageTek L1400 Tape Library - Version All Versions and laterInformation in this document applies to any platform. GoalTo provide default settings on the L1400 Interface Router to enable the hand to be mapped to a lun to be presented to the host. SolutionThese are the needed settings to be added to the Router: FIber Port 0 Link Status Link UP Port Mode Auto Sense Use Hard AL_PA Disabled Discovery Mode Discovery on Link UP Buffered Tape Writes Enabled Buffered Tape Queue Depth 1 Default Map Indexed Performance Mode 2GB Force FCP Response Code Disabled Mapping This setting must be enabled FC PORT 0 FC LUN 0 Lun 0 CHGR UP STK700 0318 (serial number shown as customer specific) If the above lun is mapped and saved, after the reboot of the router and a IPL of the library this will be active for the customer to use. References<NOTE:1364929.1> - How to Collect Statistical and Error Logs From L180/ L700e, L1400 Library:ATR:1364929.1:2<NOTE:1016817.1> - L180/L700 - Resetting Password in L-Series Library Administrator <NOTE:1301273.1> - How To Remove and Replace a Hand Camera Assembly from the L180/700/1400:ATR:965:2 <NOTE:1006640.1> - How To Get Explorer To Collect ALOM Data on V125/V210/V215/V240/V245/V440/V445 and Netra 210/240 <NOTE:1676882.1> - Policy - HOW TO upload files/logs/data to the Oracle SFTP Server Attachments This solution has no attachment |
||||||||||||||||
|