Asset ID: |
1-71-1919114.1 |
Update Date: | 2014-08-26 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1919114.1
:
Oracle Key Manager (OKM) - CommVault Error: The Media Side Mounted is Write-Protected
Related Categories |
- PLA-Support>Sun Systems>TAPE>Backup Software-Filesystems>SN-TP: Encryption
|
In this Document
Created from <SR 3-9474698186>
Applies to:
Oracle Key Manager - Version 2.5.2 and later
Information in this document applies to any platform.
Goal
What does this CommVault mount error mean?
The media side mounted is write-protected
Solution
This error may indicate that encrypted tapes are being mounted onto non-encrypted (or un-enrolled) drives.
The backup application may show ASC 0x20 (invalid operation) when the error occurs.
References
<NOTE:1447111.2> - Information Center: Oracle Key Manager (KMS/OKM) Overview Advisor
Attachments
This solution has no attachment