Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1913603.1
Update Date:2018-04-05
Keywords:

Solution Type  Technical Instruction Sure

Solution  1913603.1 :   T10000 - How To Reset The IP Address To The Factory Default  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Goal
Solution


Applies to:

StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]
StorageTek T10000C Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 Detail the process to Reset The IP Address To The Factory Default. The default IP address is 10.0.0.1.

Solution

1. Ensure the drive is not being used for anything that needs the current IP address. (encryption, SDP)

2. Find the Maintenance Switch on the back of the drive itself or on drive tray.

3. Quickly press and release this switch. Note - if the switch is pressed too long it will force a drive dump.

4. The drive IP is now set for the factory default of 10.0.01.

5. You can now connect to the drive using a machine that has the VOP application installed.

 

This is shown on page 24 and 25 of the T10000 Service Manual http://download-adc.oracle.com/archive/cd_ns/E26546_03/index.html