Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1911076.1
Update Date:2018-03-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  1911076.1 :   Emulex Installation Guide requests to install qlc patches  


Related Items
  • Netra SPARC T4-2 Server
  •  
  • Emulex FC HBA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
  •  


In the Oracle Document http://docs.oracle.com/cd/E19277-01/E20759/E20759.pdf 

on page 4 is the request to install qlc patches for an Emulex HBA , which is completely wrong:

Operating System and Technology Requirements
The HBA requires the OS and technology levels listed in TABLE 1-2

Oracle Solaris OS for the SPARC (64-bit) platform
• Oracle Solaris 10 01/13 with patches 149175-02 and 145648-04

149175-02 and 145648-04 are qlc patches and not relevant for Emulex HBAs

In this Document
Goal
Solution
References


Created from <SR 3-9393679881>

Applies to:

Netra SPARC T4-2 Server - Version All Versions to All Versions [Release All Releases]
Emulex FC HBA - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

In previous Oracle Document "StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide"

on page 4 is the request to install qlc patches for an Emulex HBA , which is completely wrong:

Operating System and Technology Requirements
The HBA requires the OS and technology levels listed in TABLE 1-2

Oracle Solaris OS for the SPARC (64-bit) platform
• Oracle Solaris 10 01/13 with patches 149175-02 and 145648-04

149175-02 and 145648-04 are qlc patches and not relevant for Emulex HBAs

 

Patch-ID# 149175-05 - Keywords: qlogic fibre channel qlogic qlc mdb macro - Synopsis: SunOS 5.10: qlc patch
--------------------------------------------------------------------------------------------------------------------------------------------------------
pure qlc patch - not needed for any emulex HBA
Files included with this patch:/kernel/drv/qlc.conf - /kernel/drv/sparcv9/qlc - /usr/lib/mdb/kvm/sparcv9/qlc.so


Patch-ID# 145648-04 - Keywords: driver fcoe qlge - Synopsis: SunOS 5.10: qlge driver Patch
-------------------------------------------------------------------------------------------------------------------------------------------------------
pure qlge patch (qlogic FCOE) - not needed for any emulex HBA

Files included with this patch: /kernel/drv/qlge.conf - /kernel/drv/sparcv9/qlge

 

But it is very important that you install the relevant Emulex Driver Patches, ie for sparc:

149173-04 5.10: emlxs driver patch [O] Emulex - Requires 144188-02

 

Solution

This has been fixed on the new document version "StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide , Part No: E20759-03 March 2015"
page 11, Table 1-2 , Supported Operating System/Technology Versions (Minimum)

Oracle Solaris OS for the x86 (64-bit) platform ■ Oracle Solaris 10 01/13 with patches 149174-04, 144189-02, and 150401-16

Oracle Solaris OS for the SPARC (64-bit) platform ■ Oracle Solaris 10 01/13 with patches 149173-04, 144188-02, and 150400-16

 

References

<NOTE:1311817.1> - Solaris[TM] 10 x86 (not SPARC) Oracle Fibre Channel (FC) HBA Driver and Firmware SAN Patch Matrix
<NOTE:1311825.1> - Solaris[TM] 10 SPARC (not x86) Oracle Fibre Channel (FC) HBA Driver and Firmware SAN Patch Matrix

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback