![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1910318.1 : SL150 - Extended Mailslot Configuration
In this Document
Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. They have tried to configure it by verifying the following procedure from this link : http://docs.oracle.com/cd/E35103_07/en/E28647/html/chapter_4.htm#i1127840. However, they didn't see option for changing. They would like to know whether they need to reset the library to factory default and then configure ? "SL150 Base module with 5 expansion modules." GoalCustomer wants to enable the 19 slot "expanded mailslot" on their SL150 tape library, current mode is "Standard(4 slots). They want to change the mode from "Standard(4 slots) to "Expanded(19 slots)". SolutionThe initial config wizard is just one of the ways to configure the "Expanded Mailslot" feature. NOTE: (10-Feb-2015) Prior to running the Configuration change, all drives MUST be unloaded. Failure to do this step will show an error stating, "All tape drives must to be unloaded prior to Partiton changes." No Data cartridges can be located in the "right hand" magazine of Module 1 at the time of mailslot expansion. Attachments This solution has no attachment |
||||||||||||||
|