Solution Type  Technical Instruction Sure

Solution  1906761.1 :   Bonding Interface Configuration Missing Primary Slave and Up Delay  


Related Items
  • Oracle Communications Subscriber Data Management (SDM)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec SDM
  •  
  • Tools>Primary Use>Configuration
  •  


blades do not have defined the "Primary Slave" and the "Up Delay" in the files /proc/net/bonding/bond0

In this Document
Goal
Solution


Created from <SR 2-9400348>

Applies to:

Oracle Communications Subscriber Data Management (SDM) - Version SDM 9.0 and later
Tekelec

Goal

Configuration has to be properly defined for bonding interface

Solution

Check the bonding configuration:

more /proc/net/bonding/bond0

Bonding Mode: fault-tolerance (active-backup)

Primary Slave: None

Currently Active Slave: eth01

Up Delay (ms): 0

 

Suggest to set "Primary Slave" to 'eth01' and "Up Delay" to 5000

 

netAdm set --device=bond0 --miimon=30 --updelay=5000 --primary=eth01