Asset ID: |
1-71-1906556.1 |
Update Date: | 2016-05-27 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1906556.1
:
Diameter Signaling Router (DSR) - How to Clear Alarm Id 32313 - Server Default Route Network Error
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-9308294171>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 4.0 and later
Information in this document applies to any platform.
Goal
How to clear Alarm Event 32313 - Server Default Route Network Error.
Solution
The issue can be corrected by issuing the following commands.
1. "syscheckAdm net defaultroute get" -- Verify if alarm is enable, alarm should be disable.
2. "syscheckAdm net defaultroute -disable" -- Disables the alarm
3. "reboot" -- the server will reset alarm settings
After executing the command the alarm will clear.
Attachments