Asset ID: |
1-71-1906530.1 |
Update Date: | 2017-02-15 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1906530.1
:
EAGLE 42.0.1 :: STP Measurements Do Not Get Transferred to Eagle Element Management System (EMS) Sometimes
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 2-9400286>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 42.x and later
Tekelec
Goal
Measurement reports sometimes did not reach the EMS server from Eagle.
During this time; Following FTP failure UAMs are observed:
****Logged 14-04-01 04:05:14****
4739.1253 CARD 1113 INFO Report transfer failure FTP Server
IP: 10.###.##.# FTP Error: 597
File Name: CLLI_abcd-sctpasoc_0401_040O,?
Report Date:14-04-01 Time:04:05:14
****Logged 14-04-01 04:05:15****
4740.1254 CARD 1113 INFO Scheduled transfer failure
IP: --------------- FTP Error: 0
File Name: -------------------------------
Report Date:14-04-01 Time:04:05:14
Solution
NOTE:
PR 210233 is already for this issue and is resolved in Eagle Release 44.0.0-64.23.0
However specifically for this customer; they had Integrated Measurements which means MCPM cards are not required to send the measurement data to EMS. However; they are still in system. They may be causing issues due to which The OAM cards are not able to transfer files properly. So I requested below mentioned steps.
1. Remove card 1101 and 1103 from the system
2. Run following to check which OAM card is active and which one is standby
a. rept-stat-card:loc=1113
b. rept-stat-card:loc=1115
Currently I see 1113 is standby and 1115 is active on this STP. In next steps; I will use them as examples
1113 133-038-017 E5MCAP OAMHC IS-NR Standby -----
1114 ----------- E5TDM IS-NR Active -----
1115 133-038-017 E5MCAP OAMHC IS-NR Active -----
1116 ----------- E5TDM IS-NR Active -----
3. Run following on standby card first
a. init-card:loc=1113 (where 1113 is location of Standby card found in step2)
4. Wait for system to come back to DUPLEX mode
5. When system is back to DUPLEX mode; run following on active card:
a. Init-card:loc=1115 (where 1115 is location of active card found in step2)
6. Wait for system to come back to DUPLEX mode
7. Wait for 15 minutes
a. rtrv-log:num=100:snum=1251:enum=1254
8. Check if alarms are not appearing now for FTP failure
Attachments
This solution has no attachment