Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1900210.1
Update Date:2014-06-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1900210.1 :   Oracle ZFS Storage Appliance: NAS in Exadata/Exalogic gets Duplicate IP Address Warnings and Disables the N/W Interfaces  


Related Items
  • Exadata X3-8b Hardware
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
  • Sun ZFS Storage 7420
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Half Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Exadata X3-2 Hardware
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Full Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Goal
Solution


Created from <SR 3-9196070959>

Applies to:

Oracle Exalogic Elastic Cloud X2-2 Full Rack - Version X3 to X4 [Release X3 to X4]
Oracle Exalogic Elastic Cloud X2-2 Half Rack - Version X4 to X4 [Release X4]
Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X4 to X4 [Release X4]
Exadata X3-8b Hardware - Version All Versions to All Versions [Release All Releases]
Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Goal

How to resolve duplicate address warnings in debug.sys and that the affected interfaces get disabled

This is normal behaviour for Solaris network interfaces when faced with other devices on the network that share the same IP address

 

Example

ip: [ID 759807 kern.warning] WARNING: ipmp2 has duplicate address xxx.xxx.xxx.x (in use by xx:00:00:xx:xx:xx:00:00:00:00:00:00:00:xx:xx:00:xx:xx:xx:x; disabled


Loss of network connectivity is the result

 

Solution

It was found that there was a Private IP address that was in conflict with new storage cell that was installed.

The NAS had its duplicate IP addresses changed to ones that did not conflict.

8 IP ZFS Storage Appliance was changed from 192.168.10.xxx - 192.168.10.xxx

    to become 192.168.11.x - 192.168.11.x  (with netmask 255.255.248.0)

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.