Solution Type Technical Instruction Sure Solution 1900210.1 : Oracle ZFS Storage Appliance: NAS in Exadata/Exalogic gets Duplicate IP Address Warnings and Disables the N/W Interfaces
In this Document
Created from <SR 3-9196070959> Applies to:Oracle Exalogic Elastic Cloud X2-2 Full Rack - Version X3 to X4 [Release X3 to X4]Oracle Exalogic Elastic Cloud X2-2 Half Rack - Version X4 to X4 [Release X4] Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X4 to X4 [Release X4] Exadata X3-8b Hardware - Version All Versions to All Versions [Release All Releases] Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) GoalHow to resolve duplicate address warnings in debug.sys and that the affected interfaces get disabled This is normal behaviour for Solaris network interfaces when faced with other devices on the network that share the same IP address
Example ip: [ID 759807 kern.warning] WARNING: ipmp2 has duplicate address xxx.xxx.xxx.x (in use by xx:00:00:xx:xx:xx:00:00:00:00:00:00:00:xx:xx:00:xx:xx:xx:x; disabled
SolutionIt was found that there was a Private IP address that was in conflict with new storage cell that was installed. The NAS had its duplicate IP addresses changed to ones that did not conflict. 8 IP ZFS Storage Appliance was changed from 192.168.10.xxx - 192.168.10.xxx