![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1684002.1 : Diameter Signaling Router (DSR) - How to Clear Alarm Event 32331 - HP disk problem. Server Disk Shelf Test Warning
In this Document
Created from <SR 2-9400492> Applies to:BNS Platform Hardware - Version DSR 4.0 and laterInformation in this document applies to any platform. GoalAlarms for HP disk on one of the DB processors. Server disk shelf test warning. EVENT_NUMBER: 32331
SEVERITY: MAJOR INSTANCE: CPQIDA-MIB::cpqDaCntlrSlot=0|CPQIDA-MIB::cpqDaLogDrvIndex=1|CPQIDA-MIB::cpqDaPhyDrvLocationString= NAME: HP disk problem DESCR: HP disk problem ERR_INFO: GN_WARNING/WRN Platform detected an error condition [cmplatalarm.cxx:269] ^^ Additional details captured in /var/TKLC/log/syscheck/fail_log (timestamp: 1400428563) [cmplatalarm.cxx:273] ^^ [5715:cmplatalarm.cxx:274] Syscheck output: [root@dsr ~]# syscheck disk
Running modules in class disk... * smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning * smart: FAILURE:: Failure type: FailedReadSmartSelfTestLog, Failure message: Device: /dev/sda [cciss_disk_01], Read SMART Self-Test Log Failed. Physical disk: 1I:1:2, Controller Slot: 0, Serial number: EA01PC31APTU1211., First occurred: Wed Apr 30 16:11:30 2014 UTC. * smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning * smart: FAILURE:: Failure type: FailedReadSmartData, Failure message: Device: /dev/sda [cciss_disk_01], failed to read SMART values. Physical disk: 1I:1:2, Controller Slot: 0, Serial number: EA01PC31APTU1211., First occurred: Wed Apr 30 16:11:30 2014 UTC. * hpdisk: FAILURE:: MAJOR::3000000080000000 -- HP Disks need intervention. * hpdisk: FAILURE:: Failure message: logicaldrive 1 for controller in slot 0 is Interim Recovery Mode. * hpdisk: FAILURE:: MAJOR::3000000080000000 -- HP Disks need intervention. * hpdisk: FAILURE:: Failure message: physicaldrive 1I:1:2 for controller in slot 0 is Failed. One or more module in class "disk" FAILED LOG LOCATION: /var/TKLC/log/syscheck/fail_log [root@dsr ~]# SolutionReplace 600gb or 300gb Hard Drive. Provided instructions below to assist with replacement of hard drive. Note the disk are hot swappable. Base on the "syscheck disk" locate the physicaldrive within the output. Example: Physical disk: 1I:1:2, modify location base on output.
Attachments This solution has no attachment |
||||||||||||||
|