Solution  1684002.1 :   Diameter Signaling Router (DSR) - How to Clear Alarm Event 32331 - HP disk problem. Server Disk Shelf Test Warning  


Related Items
  • BNS Platform Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution


Created from <SR 2-9400492>

Applies to:

BNS Platform Hardware - Version DSR 4.0 and later
Information in this document applies to any platform.

Goal

Alarms for HP disk on one of the DB processors. Server disk shelf test warning.

EVENT_NUMBER: 32331
SEVERITY: MAJOR
INSTANCE: CPQIDA-MIB::cpqDaCntlrSlot=0|CPQIDA-MIB::cpqDaLogDrvIndex=1|CPQIDA-MIB::cpqDaPhyDrvLocationString=
NAME: HP disk problem
DESCR: HP disk problem
ERR_INFO:
  GN_WARNING/WRN Platform detected an error condition [cmplatalarm.cxx:269]
 ^^ Additional details captured in /var/TKLC/log/syscheck/fail_log (timestamp: 1400428563) [cmplatalarm.cxx:273]
 ^^ [5715:cmplatalarm.cxx:274]

Syscheck output:

[root@dsr ~]# syscheck disk
Running modules in class disk...
* smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
* smart: FAILURE:: Failure type: FailedReadSmartSelfTestLog, Failure message: Device: /dev/sda [cciss_disk_01], Read SMART Self-Test Log Failed. Physical disk: 1I:1:2, Controller Slot: 0, Serial number: EA01PC31APTU1211., First occurred: Wed Apr 30 16:11:30 2014 UTC.
* smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
* smart: FAILURE:: Failure type: FailedReadSmartData, Failure message: Device: /dev/sda [cciss_disk_01], failed to read SMART values. Physical disk: 1I:1:2, Controller Slot: 0, Serial number: EA01PC31APTU1211., First occurred: Wed Apr 30 16:11:30 2014 UTC.
* hpdisk: FAILURE:: MAJOR::3000000080000000 -- HP Disks need intervention.
* hpdisk: FAILURE:: Failure message: logicaldrive 1 for controller in slot 0 is Interim Recovery Mode.
* hpdisk: FAILURE:: MAJOR::3000000080000000 -- HP Disks need intervention.
* hpdisk: FAILURE:: Failure message: physicaldrive 1I:1:2 for controller in slot 0 is Failed.
One or more module in class "disk" FAILED

LOG LOCATION: /var/TKLC/log/syscheck/fail_log
[root@dsr ~]#

Solution

Replace 600gb or 300gb Hard Drive. Provided instructions below to assist with replacement of hard drive. Note the disk are hot swappable.

Base on the "syscheck disk" locate the physicaldrive within the output. 

Example: Physical disk: 1I:1:2, modify location base on output.

  1. # syscheck -v disk hpdisk  (note: the output here would also confirm the disk failure. If no failure is shown then run commands 4, 5 and 6 below to clear the alarm. If there is a failure then continue with the steps as outlined.)
  2. # hpacucli ctrl slot=0 physicaldrive 1I:1:2 modify led=on (look for blue led on HD)
  3. ******Replace Hard Drive*******
  4. # syscheck --reconfig disk smart
  5. # service smartd restart
  6. # syscheck disk smart
  7. # syscheck disk
  8. # hpacucli ctrl slot=0 pd all show status
  9. # hpacucli ctrl slot=0 ld all show status (Track syncing progress with this command. NOTE: This could take more than 90 minutes to complete)
  10. # syscheck
  11. # hpacucli ctrl slot=0 physicaldrive 1I:1:2 modify led=off