Replacement instructions for Coupler and internal FC cable on SL8500 LTO drive tray.

In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: General advice for FEs
Created from <SR 3-9132122812>

Applies to:

HP LTO3 Tape Drive - Version All Versions to All Versions [Release All Releases]
HP LTO4 Tape Drive - Version All Versions and later
HP LTO5 Tape Drive - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

HP LTO drive tray
SL8500

Goal

Changing the FC coupler and drive tray cable on a SL8500 LTO drive tray.

Replacement instructions for Coupler and internal FC cable on SL8500 LTO drive tray.

Solution


1. Remove drive from library  (see Doc 1353584.1).

2. Disconnect the cable assembly.

3. Clip and discard all cable tie/mounts securing the cable assembly to the tray assembly.

4. Remove the T10 mounting screw on the drive interface plate.

5. Pull the plate away from the drive tray rear panel to access and disconnect the rear fibre-optic cable connector.

6. Remove coupler.

7. Follow cable and remove from opposite end of cable from drive.

8. Connect the replacement cable assembly.

9. Replace coupler.

10. Secure the cable assembly to the tray assembly with new cable/tie mounts.

11. Reattach the drive interface plate to the drive tray rear panel with one T10 screw.

Part numbers for cables vary according to the drive type.  Please refer to the SL8500 Sun System Handbook.

Full parts installation instructions are in the SL8500 Service Manual.


Note: Low Light levels reported when testing FC port.

References

<NOTE:1377490.1> - SL500/SL3000/SL8500 - Procedure for Collecting One Button Log Snapshot From Library
<NOTE:1353584.1> - How to Remove and Replace a Tape Drive in SL8500:ATR:1353584.1:2