Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1679586.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1679586.1 :   How to Remove and Replace Sun Blade 1000/2000 PCI card:ATR:1679586.1:0  


Related Items
  • Sun Blade 1000 Workstation
  •  
  • Sun Blade 2000 Workstation
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Blade 2000 Workstation - Version Not Applicable and later
Sun Blade 1000 Workstation - Version Not Applicable and later
Information in this document applies to any platform.

Goal

   Sun Blade 1000, Sun Blade 2000, How to Remove and Replace PCI card

**********************************************************************
To report errors or request improvements on this procedure,
please Add a comment on Doc ID: 1487890.1
**********************************************************************

Solution

 

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TASK COMPLEXITY: 1

TIME ESTIMATE: 45 minutes

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: PCI failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTIONS ARE REQUIRED:

Removing a PCI Card
1. Power off the workstation, remove the access panel, and attach the antistatic wrist strap.

2. Disconnect any external cables from the PCI card that you plan to remove.

3. Lay the workstation on its side.

Caution – Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in
antistatic bags before placing them on any surface.

Note – To remove extra-long PCI cards, detach the fan bracket tabs and pull the bracket back out of the way.

4. Using a No. 2 Phillips screwdriver, remove the screw securing the PCI card bracket tab to the workstation chassis.
Caution – Avoid damaging the connector by not applying force to one end or one side of the board.

5. Pull the upper two corners of the card straight up from the connector.

6. Remove the PCI card.

7. Place the PCI card on an antistatic mat.

Replacing a PCI Card
Perform the following procedures to replace a PCI card.

Caution – Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in
antistatic bags before placing them on any surface.

Note – Read the PCI card product guide for information about jumper or switch settings, connector requirements, and required tools.
Note – To insert extra-long PCI cards, detach the fan bracket tabs and pull the bracket back out of the way.

1. Position the PCI card in the chassis.

2. Guide the card bracket tab into the chassis back-panel opening. Guide the opposite end of the card into the fan bracket card guide so that the card is aligned
evenly with the motherboard connector.

3. At the two upper corners of the PCI card, push the PCI card straight down into the connector until the PCI card is fully seated.

4. Using a No. 2 Phillips screwdriver, replace the screw securing the PCI card bracket tab to the workstation chassis.
Note – If you have removed the fan bracket for extra-long PCI cards, replace it by latching it into the slots in the chassis.

5. If necessary, reattach the fan bracket removed earlier.

6. Connect any cables to the PCI boards.

7. Detach the antistatic wrist strap, replace the access panel, and power on the workstation.

8. Verify proper operation.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE: Include PCI location:

https://support.oracle.com/handbook_private/Systems/SunBlade1000/components.html

https://support.oracle.com/handbook_private/Systems/SunBlade2000/components.html

 

REFERENCES:

Please refer to the

Sun Blade 1000 and Sun Blade 2000 Service Manual http://docs.oracle.com/cd/E19127-01/blade2000.ws/816-3217-10/816-3217-10.pdf


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback