![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1679571.1 : How to Remove and Replace Sun Blade 1000/2000 Power Supply:ATR:1679571.1:1
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Sun Blade 2000 Workstation - Version Not Applicable and laterSun Blade 1000 Workstation - Version Not Applicable and later Information in this document applies to any platform. GoalSun Blade 1000, Sun Blade 2000, How to Remove and Replace Hard Disk ********************************************************************** Solution
DISPATCH INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE: Removing the Power Supply Assembly 1. Power off the workstation and remove the access panel. 2. Squeeze the connectors to disengage them from the motherboard. Now, disconnect the two power supply assembly connectors, J3601 and J3603, from the motherboard. 3. Loosen the reusable cable tie in the upper-right corner of the chassis cutout that secures the two power supply cables. 4. Using a No. 2 Phillips screwdriver, remove the six screws securing the power supply assembly to the chassis back panel. 5. Remove the power supply from the chassis by pulling on the power supply assembly handle. Note – Support the power supply assembly with one hand as you remove it from the chassis.
Replacing the Power Supply Assembly Perform the following procedures to remove and replace the power supply assembly. Caution – Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in 1. Tuck the power supply cables into the plastic retainer bracket 2. Place the power supply into the chassis. 3. Tip up the front of the power supply as you slide it in the chassis, so that the front edge of the power supply engages the chassis tab under the motherboard. 4. Pull the power supply cables through the cutout at the upper-right corner of the motherboard. 5. Connect the power supply assembly connectors to the motherboard connectors J3601 and J3603. 6. Attach the reusable cable tie around the power supply cables. 7. Using a No. 2 Phillips screwdriver, replace the six screws securing the power supply assembly to the chassis back panel. 8. Detach the antistatic wrist strap, replace the access panel, and power on the workstation. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FE/ADMINISTRATOR NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE: https://support.oracle.com/handbook_private/Systems/SunBlade1000/components.html https://support.oracle.com/handbook_private/Systems/SunBlade2000/components.html REFERENCES: Sun Blade 1000 and Sun Blade 2000 Service Manual http://docs.oracle.com/cd/E19127-01/blade2000.ws/816-3217-10/816-3217-10.pdf Attachments This solution has no attachment |
||||||||||||||
|