Asset ID: |
1-71-1679568.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1679568.1
:
How to Remove and Replace Sun Blade 1000/2000 Disk Drive:ATR:1679568.1:0
Related Items |
- Sun Blade 1000 Workstation
- Sun Blade 2000 Workstation
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Blade 2000 Workstation - Version Not Applicable and later
Sun Blade 1000 Workstation - Version Not Applicable and later
Information in this document applies to any platform.
Goal
Sun Blade 1000, Sun Blade 2000, How to Remove and Replace Hard Disk
**********************************************************************
To report errors or request improvements on this procedure,
please Add a comment on Doc ID: 1487890.1
**********************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TASK COMPLEXITY: 0
TIME ESTIMATE: 40 minutes
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: Disk failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTIONS ARE REQUIRED:
Perform the following procedures to remove and replace a hard drive.
Note – When removing or replacing a hard drive, drive slot 1 is in the bottom position of the hard drive bracket. Drive slot 2 is in the upper position of the hard drive bracket.
Note – If only one hard drive is installed on the workstation or if you only want to boot from a specific drive, that hard drive must be installed in drive slot 1 in the bottom position of the hard drive bracket.
Removing a Hard Drive
1. Power off the workstation, remove the access panel, and attach the antistatic wrist strap.
Caution – Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in antistatic bags before placing them on any surface.
2. Release the drive handle by pushing the handle release button toward the front of the chassis housing.
3. Pull out on the drive handle to disconnect the hard drive from the FC-AL backplane assembly connector.
4. Remove the hard drive from the hard drive bracket.
5. Place the hard drive on an antistatic mat.
Replacing a Hard Drive
Caution – Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in
antistatic bags before placing them on any surface.
1. Holding the drive handle, insert the hard drive into the hard drive bracket along the vertical plastic guides until the hard drive handle starts to close.
2. Close the hard drive handle to lock the hard drive into the hard drive bracket.
3. Detach the antistatic wrist strap, replace the access panel, and power on the workstation.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: Include Disk location:
https://support.oracle.com/handbook_private/Systems/SunBlade1000/components.html
https://support.oracle.com/handbook_private/Systems/SunBlade2000/components.html
REFERENCES:
Please refer to the
Sun Blade 1000 and Sun Blade 2000 Service Manual http://docs.oracle.com/cd/E19127-01/blade2000.ws/816-3217-10/816-3217-10.pdf
Attachments