Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1679313.1
Update Date:2015-10-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1679313.1 :   VSM - How Many Disk Drives (HDAs) Can Fail in a 32 Drive Configuration Without Losing Any Data  


Related Items
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Goal
Solution


Created from <SR 3-9070858771>

Applies to:

Sun StorageTek VSM5 System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Qn1:How many HDAs can you lose in a VSM5 in a 32 drive configuration before potential data loss?
 

Solution

 

 

1. With a VSM with 32 drives (RAID6), you can lose two drives anywhere and still have all of your production drives in each array, but no spares available.
2. If you lose two more production drives within a logical array while your spares are in use, you still maintain error correction and no loss of data.
3. If you lose a 3rd drive within a logical array you now have a data loss situation.

Note - So you can loose 4 drives and still operate in a 32 drive configuration, but do not ever let the VSM get to that point.