How to boot a T5-2 from a hardware RAID Volume
Related Items |
- SPARC T3-4
- SPARC T3-1
- SPARC T4-2
- SPARC T5-8
- SPARC T5-2
- SPARC T5-4
- SPARC T4-1
- SPARC T3-2
- SPARC T4-4
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
|
Created from <SR 3-8972477411>
Applies to:
SPARC T5-2 - Version All Versions and later
SPARC T5-4 - Version All Versions and later
SPARC T5-8 - Version All Versions and later
SPARC T4-1 - Version All Versions and later
SPARC T4-2 - Version All Versions and later
Information in this document applies to any platform.
Goal
Once hardware RAID volumes are created, ensure that they are in an optimal state.
{0} ok show-volumes
Volume 0 Target 143 Type RAID1 (Mirroring)
Name glue-sys WWID 0c605f5c4c5e5c4e
Optimal Enabled Background Init In Progress
2 Members 583983104 Blocks, 298 GB
Disk 1
Primary Optimal
Target 9 HITACHI H109030SESUN300G A606 PhyNum 0
Disk 0
Secondary Optimal
Target a HITACHI H109030SESUN300G A606 PhyNum 1
Then, use probe-scsi-all to obtain the volume's controller path & VolumeDeviceName:
{0} ok probe-scsi-all
...
/pci@300/pci@1/pci@0/pci@2/scsi@0
FCode Version 1.00.63, MPT Version 2.00, Firmware Version 14.00.00.00
Target 143 Volume 0
Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
VolumeDeviceName 3c605f5c4c5e5c4e VolumeWWID 0c605f5c4c5e5c4e
Solution
Boot from the "path"/disk@w"VolumeDeviceName" from the probe-scsi-all:
{0} ok boot /pci@300/pci@1/pci@0/pci@2/scsi@0/disk@w3c605f5c4c5e5c4e
Please note that the internal disk controller paths are:
T3-1 & T4-1:
/pci@400/pci@1/pci@0/pci@4/scsi@0
/pci@400/pci@2/pci@0/pci@4/scsi@0
T3-2 & T4-2:
/pci@400/pci@2/pci@0/pci@e/scsi@0
T3-4 & T4-4:
/pci@400/pci@1/pci@0/pci@0/scsi@0
/pci@500/pci@2/pci@0/pci@0/scsi@0
/pci@700/pci@1/pci@0/pci@0/scsi@0
T5-1S:
/pci@300/pci@1/pci@0/pci@2/scsi@0
/pci@340/pci@1/pci@0/pci@2/scsi@0
T5-2:
/pci@300/pci@1/pci@0/pci@2/scsi@0
/pci@3c0/pci@1/pci@0/pci@2/scsi@0
T5-4:
/pci@300/pci@1/pci@0/pci@4/pci@0/pci@c/scsi@0
/pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0
T5-8:
/pci@300/pci@1/pci@0/pci@4/pci@0/pci@c/scsi@0
/pci@6c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0