Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1670532.1
Update Date:2017-11-03
Keywords:

Solution Type  Technical Instruction Sure

Solution  1670532.1 :   How to boot a T5-2 from a hardware RAID Volume  


Related Items
  • SPARC T3-4
  •  
  • SPARC T3-1
  •  
  • SPARC T4-2
  •  
  • SPARC T5-8
  •  
  • SPARC T5-2
  •  
  • SPARC T5-4
  •  
  • SPARC T4-1
  •  
  • SPARC T3-2
  •  
  • SPARC T4-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  




Created from <SR 3-8972477411>

Applies to:

SPARC T5-2 - Version All Versions and later
SPARC T5-4 - Version All Versions and later
SPARC T5-8 - Version All Versions and later
SPARC T4-1 - Version All Versions and later
SPARC T4-2 - Version All Versions and later
Information in this document applies to any platform.

Goal

Once hardware RAID volumes are created, ensure that they are in an optimal state.


{0} ok show-volumes
Volume 0 Target 143 Type RAID1 (Mirroring)
  Name glue-sys WWID 0c605f5c4c5e5c4e
  Optimal Enabled Background Init In Progress
  2 Members 583983104 Blocks, 298 GB
  Disk 1
  Primary Optimal
  Target 9 HITACHI H109030SESUN300G A606 PhyNum 0
  Disk 0
  Secondary Optimal
  Target a HITACHI H109030SESUN300G A606 PhyNum 1

 
Then, use probe-scsi-all to obtain the volume's controller path & VolumeDeviceName:

{0} ok probe-scsi-all
...
/pci@300/pci@1/pci@0/pci@2/scsi@0

FCode Version 1.00.63, MPT Version 2.00, Firmware Version 14.00.00.00

Target 143 Volume 0
  Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
  VolumeDeviceName 3c605f5c4c5e5c4e VolumeWWID 0c605f5c4c5e5c4e
 

Solution

Boot from  the "path"/disk@w"VolumeDeviceName" from the probe-scsi-all:

{0} ok boot /pci@300/pci@1/pci@0/pci@2/scsi@0/disk@w3c605f5c4c5e5c4e

Please note that the internal disk controller paths are:

T3-1 & T4-1:
  /pci@400/pci@1/pci@0/pci@4/scsi@0
  /pci@400/pci@2/pci@0/pci@4/scsi@0

T3-2 & T4-2:
  /pci@400/pci@2/pci@0/pci@e/scsi@0

T3-4 & T4-4:
  /pci@400/pci@1/pci@0/pci@0/scsi@0
  /pci@500/pci@2/pci@0/pci@0/scsi@0
  /pci@700/pci@1/pci@0/pci@0/scsi@0

 

T5-1S:
  /pci@300/pci@1/pci@0/pci@2/scsi@0
  /pci@340/pci@1/pci@0/pci@2/scsi@0

T5-2:
  /pci@300/pci@1/pci@0/pci@2/scsi@0
  /pci@3c0/pci@1/pci@0/pci@2/scsi@0

T5-4:
  /pci@300/pci@1/pci@0/pci@4/pci@0/pci@c/scsi@0
  /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0

T5-8:
  /pci@300/pci@1/pci@0/pci@4/pci@0/pci@c/scsi@0
  /pci@6c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0

 