![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1666335.1 : Bootloader requirements for loading SCZ7 onto a 4500 or 3820
In this Document
Created from <SR 3-8888048751> Applies to:Acme Packet 4500 - Version S-Cx6.1.0 to S-Cz7.4.0 [Release S-Cx6.0 to S-Cz7.0]Acme Packet 3820 - Version S-Cx6.1.0 to S-Cz7.4.0 [Release S-Cx6.0 to S-Cz7.0] Acme Packet 4500 Acme Packet 3820 GoalWhat are the bootloader requirements for loading SCZ7.X.X on a 4500 or 3820 system? SolutionThe stage1 and 2 bootloader file should be dated minimum 3rd July 2013. The stage 3 bootloader should match the version of software running on the 4500. The stage3 bootloader is provided as a .boot file along with the image which needs to be renamed as bootloader and copied to boot directory.
Acme Packet 3820 and 4500 Bootloader Prerequisites Customers planning to upgrade to Oracle Session Delivery software version 7 and beyond on Acme Packet 3820 and 4500 hardware must first upgrade their boot loader to the image dated July 03, 2013 or later.
References<NOTE:1587188.1> - How to Verify the Version of Bootloader on a Net-Net 4500 and Net-Net 3820<NOTE:1640605.1> - How to find Acme Packet Bootloader and Diagnostics files on MOS Patches and Updates Attachments This solution has no attachment |
||||||||||||||||
|