Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1666335.1
Update Date:2017-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1666335.1 :   Bootloader requirements for loading SCZ7 onto a 4500 or 3820  


Related Items
  • Acme Packet 3820
  •  
  • Acme Packet 4500
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
  •  




In this Document
Goal
Solution
References


Created from <SR 3-8888048751>

Applies to:

Acme Packet 4500 - Version S-Cx6.1.0 to S-Cz7.4.0 [Release S-Cx6.0 to S-Cz7.0]
Acme Packet 3820 - Version S-Cx6.1.0 to S-Cz7.4.0 [Release S-Cx6.0 to S-Cz7.0]
Acme Packet 4500
Acme Packet 3820

Goal

What are the bootloader requirements for loading SCZ7.X.X  on a 4500 or 3820 system?

Solution

The stage1 and 2 bootloader file should be dated minimum 3rd July 2013. The stage 3 bootloader should match the version of software running on the 4500. The stage3 bootloader is provided as a .boot file along with the image which needs to be renamed as bootloader and copied to boot directory.

 

Acme Packet 3820 and 4500 Bootloader Prerequisites

Customers planning to upgrade to Oracle Session Delivery software version 7 and beyond on Acme Packet 3820 and 4500 hardware must first upgrade their boot loader to the image dated July 03, 2013 or later.

  • The AP 3820 and AP 4500 require Stage 1, Stage 2, and Stage 3 bootloaders.
  • The Stage 1 and Stage 2 bootloaders should be dated no earlier than July 3, 2013 (MOS patch # 18185632) . Use the show version boot command to view current bootloader version on your system.
  • THe Stage 1 and Stage 2 bootloader updates are available on My Oracle Support listed under the respective hardware.
  • The Stage 3 bootloader accompanies the OCSBC image file, as distributed. It should be installed according to the instructions found in the Maintenance and Troubleshooting Guide.

 

References

<NOTE:1587188.1> - How to Verify the Version of Bootloader on a Net-Net 4500 and Net-Net 3820
<NOTE:1640605.1> - How to find Acme Packet Bootloader and Diagnostics files on MOS Patches and Updates

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback