![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1665112.1 : [SPARC T5-4 and T5-8] How to physically locate the rear fan based on system messages
In this Document
Created from <SR 3-8698617493> Applies to:SPARC T5-8 - Version All Versions to All Versions [Release All Releases]SPARC T5-4 - Version All Versions to All Versions [Release All Releases] Oracle SuperCluster T5-8 Full Rack - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalThe SPARC T5-4 and SPARC T5-8 ILOM reports critical System Fan events on the ILOM system logs or Solaris system messages log Example ( Solaris System Messages ) Mar 13 13:23:12 NODE1 SC Alert: [ID 472888 daemon.error] Chassis | major: Hot removal of /SYS/RCSA/FBD0/FM4 Mar 13 13:23:12 NODE1 SC Alert: [ID 382037 daemon.notice] SDM | minor: Fan Module Removed from location FBD0/FM4 (Fan Board 0 Fan Module 4). Mar 13 13:23:12 NODE1 SC Alert: [ID 296258 daemon.alert] Fault | critical: Fault detected at time = Thu Mar 13 13:23:12 2014. The suspect component: /SYS has fault.component.missing with probability=100. Refer to http://support.oracle.com/msg/SPT-8000-J4 for details. The ILOM message uses the naming convention of /SYS/RCSA/FBDx/FMx in reporting Fan related events. On the rear of the SPARC T5-4 and T5-8 system a vertical label is present in the FAN slots with the format FBDx/FMx . The vertical label is not explicitly mentioned in the system documentation for T5-4 and T5-8 systems. Example
SolutionT5-8 Fan Location
T5-4 Fan Location
Attachments This solution has no attachment |
||||||||||||||
|