Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1662989.1
Update Date:2017-07-11
Keywords:

Solution Type  Technical Instruction Sure

Solution  1662989.1 :   How to check the uptime of the OPUS switch and its SEFOS  


Related Items
  • Sun Network Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Goal
Solution
References


Created from <SR 3-8654869301>

Applies to:

Sun Network Switch - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to check the uptime of the Opus switch and sefos

Solution

 The uptime of the switch and of sefos can be gathered through the ILOM commands: 


  -> show /SP/clock/ uptime               

      /SP/clock

      Properties:

      uptime = 4 days, 04:40:08           <---- displays the uptime of the switch

 

  -> show /SYS/sefos/ uptime       

      /SYS/sefos

      Properties:

      uptime = 4 days, 04:38:28         <----  displays the uptime of sefos

  

Please note, There is currently not method to determine the uptime of the switch through snmp. 

The SNMP MIB object sysUpTime does not relate to the uptime of the switch, it relates to the uptime of the snmp agent on the switch. The snmp agent can restart due to a variety of reasons, neither of which affect the operation of the switch. 
 


References

<BUG:18456572> - FALSE READING FROM OID DISMAN-EVENT-MIB::SYSUPTIMEINSTANCE 1.3.6.1.2.1.1.3
<NOTE:1399483.1> - 10-Gigabit Ethernet Switches (Opus) Product Page