Solution Type Technical Instruction Sure Solution 1644931.1 : NON-Solaris Fibre Channel (FC) HBA Port LED Based Testing When Another Working FC HBA Port Is Available
In this Document
Created from <SR 3-8677187481> Applies to:Sun Fire X4100 M2 Server - Version All Versions and laterEmulex FC HBA - Version All Versions to All Versions [Release All Releases] Qlogic FC HBA - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalTo determine if FC hba port can log onto a FC Switch and/or FC Storage device.
For Solaris systems see following doc: Using Solaris Fibre Channel (FC) Loopback Plug or Private Loop Cable to Test FC HBA Port That Is In a Offline State(Doc ID 1610207.1)
SolutionNote: This is a disruptive test that should only be done during system idle or maintenance time when no active IO is occuring.
1 - Make note of the fc hba port LED pattern of the working fc hba port.
2 - Make note of the fc hba port LED pattern of the NON-working fc hba port.
3 - Swap the fc hba end of cable between the non-working and working fc hba ports.
If the NON-working fc hba port now shows the working LED pattern then issue is outside the fc hba port. Check components between fc hba port and fc switch/storage, as well as, the fc switch/storage port.
If the NON-working fc hba port still shows the NON-working LED pattern then fc hba card will need to be replaced.
See following doc for info needed by Oracle support when a Oracle Service Request (SR) is opened. Fibre Channel (FC) Server-Based Connectivity Issues - Basic information and data needed by Oracle support (Doc ID 1449557.1) References<NOTE:166650.1> - Working Effectively With Oracle Support - Best PracticesAttachments This solution has no attachment |
||||||||||||||||
|